Switchgear and Protection SPPU Endsem Question Paper May 2024
All 8 questions from this SPPU endsem paper, as printed. Read them here or open the PDF.
- Subject code
- 403148
- Pattern
- 2019 pattern
- Exam
- Endsem
- Session
- May 2024
- Max. marks
- 70
- Time
- 2½ Hours
- Semester
- VIII
- Paper code
- [6263]-114
Printed for: B.E. (Electrical Engineering)
Instructions to the candidates
- Solve Q1 or Q2, Q3 or Q4, Q5 or Q6, Q7 or Q8.
- Figures to the right indicate full marks.
- Neat diagrams must be drawn wherever necessary.
- Assume suitable additional data, if necessary.
- Use of non - programmable calculator is allowed.
Questions
Q1
- a)[4]
Explain the following terms with respect to circuit breaker. i) Breaking capacity ii) Making capacity
- b)[6]
What is Auto Reclosing? Discuss single shot and multi shot auto reclosing of circuit breakers.
Also asked:May 2023
- c)[8]
Draw neat diagram and explain the construction and working principle of vacuum circuit breaker?
Also asked:May 2023
OR- a)
Q2
- a)[4]
A 3 phase VCB is rated as 1500 A, 2000 MVA, 33kV, 1 seconds. Determine - i) Symmetrical breaking current ii) Rated making current iii) Short time current iv) Rated normal current
- b)[6]
State the advantages & disadvantages of GIS.
- c)[8]
Explain physical, chemical & dielectric properties of SF6 gas which makes it to use as arc interrupting medium in SF6 CB?
- a)
Q3
- a)[10]
With neat block diagram explain working of Numerical relay. Also state its advantages over static & conventional relay.
Also asked:Nov 2023
- b)[7]
Draw and explain the block diagram of PMU. 2
OR- a)
Q4
Q5
- a)[4]
Explain the phenomenon of over fluxing in the transformer. Suggest the protection scheme used in this case.
- b)[6]
Explain with neat diagram single phase preventer in case of three phase induction motor.
- c)[8]
With neat diagram explain working of Buchholz relay. State its advantages & disadvantages.
OR- a)
Q6
- a)[4]
Draw & explain the protection of 3 phase alternators against inter turn faults on same phase.
Also asked:Nov 2023
- b)[6]
Explain the abnormal conditions like i) Unbalance loading and ii) loss of prime mover in case of alternator.
- c)[8]
A three phase, 66kV/11kV, Delta-Star connected power transformer is protected by differential protection. The CTs on the LV side have a current ratio of 420/5. What must be the current ratios of CTs on the HV side? Draw a neat connection diagram of the scheme.
- a)
Q7
- a)[10]
What do you mean by under reach and over reach in case of distance relay? Compare impedance relay, reactance relay and mho relay on the basis of its characteristics on R-X plane, applications, effect of arc resistance.
- b)[7]
Explain the three stepped distance protection for transmission line with neat diagram.
OR- a)
Q8
- a)[10]
Explain the effect of (i) power swings and (ii) arc resistance on the performance of the distance relay. Mention which relay gets highly affected in each case.
- b)[7]
Draw block diagram and explain components of power line carrier communication (PLCC) for long transmission lines.
- a)