Questions

  1. Q1

    1. a)

      What is auto reclosing of circuit breaker? Discuss multi shot auto reclosing.

      Also asked:May 2024

      [4]
    2. b)

      Mention the advantages and disadvantages of GIS as compared to conventional air insulated substation.

      [6]
    3. c)

      With neat diagram explain the construction & working of Puffer type SF6 circuit breaker.

      Also asked:Nov 2025

      [8]
  2. Q2

    1. a)

      A 3 phase VCB is rated as 1500 A, 2000 MVA, 33 kV, 3 seconds. Determine i) Symmetrical breaking current ii) Rated making current iii) Short time current iv) Rated normal current

      Also asked:Nov 2025 ·May 2025 ·May 2024 ·Nov 2023

      [4]
    2. b)

      What is difference between field testing and laboratory testing? Explain the relative merits of each.

      [6]
    3. c)

      With neat diagrm explain the construction & working of Vacuum circuit breaker.

      Also asked:May 2024

      [8]
  3. Q3

    1. a)

      Draw block diagram of static relay. Explain its working. State merits and demerits of static relay.

      [10]
    2. b)

      Draw and explain block diagram of PMU. 2

      [7]
  4. Q4

    1. a)

      Draw a block diagam of numerical relay. Explain its woking. State its advantages over conventioinal and static relays.

      [10]
    2. b)

      State Sampling theorem. What is Aliasing? Explain it with neat diagram.

      [7]
  5. Q5

    1. a)

      Restricted earth fault protection of 3 phase alternator gives 100% stator winding protection-Justify the statement stating True/False.

      [4]
    2. b)

      Discuss various abnormal operating conditions & causes of failures in 3 phase induction motor.

      [6]
    3. c)

      Suggest suitable protection scheme to protect power transformer against the magnetic inrush current phenomenon. With neat diagram explain the protection scheme in this case.

      [8]
  6. Q6

    1. a)

      Discuss abnormal condition-Over speeding in case of 3 phase alternator. Suggest protection scheme in this case.

      [4]
    2. b)

      List out different types of faults in alternator. Suggest suitable protection scheme to protect alternator against these faults.

      [6]
    3. c)

      A three phase 33kV/3.3kV, star/delta connected transformer is protected by percentage differential protection. The CTs on LT side have ratio of 400/5. Determine he CT ratio on HT side. Draw the protection scheme.

      Also asked:Nov 2023

      [8]
  7. Q7

    1. a)

      With suitable diagrams explain the effect of i) arc resistance ii) power swing on the operation of distance relay.

      Also asked:Nov 2025 ·May 2025 ·Nov 2024 ·May 2024 ·Nov 2023

      [10]
    2. b)

      Draw the schematic of PLCC. State advantages of PLCC.

      [7]
  8. Q8

    1. a)

      Draw block diagram of numerical impedance relay. Explain its working. Draw its algorithm.

      [10]
    2. b)

      With neat diagram explain three stepped distance protection scheme for transmission line. 

      Also asked:Nov 2025 ·Nov 2024 ·May 2024

      [7]