Electrical Machines-II SPPU Insem Question Paper Oct 2024
All 4 questions from this SPPU insem paper, as printed. Read them here or open the PDF.
- Subject code
- 303143
- Pattern
- 2019 pattern
- Exam
- Insem
- Session
- Oct 2024
- Max. marks
- 30
- Time
- 1 Hour
- Semester
- I
- Paper code
- [6360]-35
Printed for: T.E. (Electrical Engineering) (Insem)
Instructions to the candidates
- Solve Q1 or Q2, Q3 or Q4.
- Neat Diagrams must be drawn wherever necessary.
- Figures to the right indicate full marks.
- Use of electronic pocket calculator is allowed.
- Assume suitable data if necessary.
Questions
Q1
- a)[7]
Why rotating field & stationary armature type of construction is preferred for 3-ph alternator.
- b)[8]
Calculate the no load emf of a star connected 3-ph , 6 pole alternator which is driven at 1200 rpm having flux per pole 0.12 Wb. The armature has 54 slots and double layer winding. Each coil has 10 turns & coil is short chorded by two slots.
OR- a)
Q2
- a)[7]
Draw the circuit diagram & explain the procedure to conduct slip test on salient pole 3-ph alternator to determine voltage regulation. Write the necessary formulae.
- b)[8]
This part has equations that don’t show as text. Open the PDF to read it.
- a)
Q3
- a)[7]
Sketch the OCC and SCC of alternator & write down the steps to determination of voltage regulation of 3-ph alternator at lagging power factor by MMF method analytically. Assume Ra = 0.
Also asked:Aug 2025
- b)[8]
A 2000 kVA, 2300V, 3-ph star connected alternator has armature resistance of 0.06 per phase. A field current 60 A, produces armature current of 600A and no load line emf of 900 V. Calculate (i) full load voltage regulation at 0.8 p.f lagging & (ii) power angle .
OR- a)
Q4
- a)[7]
Define & explain the short circuit ratio using OCC & SCC plots. Comment on voltage regulation for (i) for higher value of SCR (ii) lower value of SCR.
- b)[8]
This part has equations that don’t show as text. Open the PDF to read it.
- a)