Electrical Machines-II SPPU Insem Question Paper Oct 2023
All 4 questions from this SPPU insem paper, as printed. Read them here or open the PDF.
- Subject code
- 303143
- Pattern
- 2019 pattern
- Exam
- Insem
- Session
- Oct 2023
- Max. marks
- 30
- Time
- 1 Hour
- Semester
- I
- Paper code
- [6187]-435
Printed for: T.E.(Electrical Engineering) (Insem.)
Instructions to the candidates
- Solve Q1 or Q2, Q3 or Q4.
- Figures to the right indicate full marks.
- Neat diagrams must be drawn wherever necessary.
- Assume suitable additional data, if necessary.
- Use of non-programmable calculator is allowed.
Questions
Q1
- a)[7]
Compare the salient pole rotor construction with non salient pole rotor construction in case of synchronous machine. (any 7 points)
Also asked:Aug 2025
- b)[8]
A 3 phase, 50 Hz, 8 pole star connected alternator has 72 slots on the armature. Each slot has 12 conductors and winding is shorted by 2 slots. Calculate the induced emf between the lines if the flux per pole is 0.06 Weber.
OR- a)
Q2
- a)[7]
What is armature reaction in case of 3 phase synchronous machine? Elaborate its effect at zero lagging power factor with the help of neat waveform and vector diagram.
Also asked:Aug 2025
- b)[8]
Test results of Slip test conducted on 3 phase, 415 V, 3 kVA star connected salient pole alternator are shown below. V max (line) V min(line) Ia max Ia min 45 V 40 V 1.3 A 1.1A Assume Ra= 0 ohms per phase. Determine direct axis synchronous reactance, quadrature axis synchronous reactance. Hence determine voltage regulation at full load 0.8 pf lagging.
- a)
Q3
- a)[7]
Explain the need of synchronisation of alternators. State the conditions of parallel operation of alternators.
- b)[8]
A 1200 kVA, 3300 volts 50 Hz 3 phase star connected alternator has armature resistance of 0.25 ohm per phase. A field current of 40 A produces a short circuit current of 209.95 A and the same field current of 40 A produces an open circuit emf of 1100 V (line). Calculate the voltage regulation of alternator on - full load 0.8 lagging power factor.
OR- a)
Q4
- a)[7]
What is Short Circuit Ratio in case of alternator? Elaborate its significance. State its value for turbo alternators and hydro generators.
- b)[8]
Sketch and label OCC, ZPFC & Potier triangle. Based on this information, how voltage regulation can be calculated analytically at lagging power factor by Potier method?
- a)